The MNB data centre has received TIER III certification in collaboration with H1 Systems

The MNB data centre has received TIER III certification in collaboration with H1 Systems 800 450 H1 Systems Mérnöki Szolgáltatások Kft.

A new milestone has been reached in the Hungarian data centre sector: the server facility established on behalf of the Hungarian National Bank has obtained the Uptime Institute TIER III Constructed Facility certification. This internationally recognised certification not only confirms the compliance of the design but also demonstrates that the completed infrastructure is capable of meeting the strictest requirements for availability, reliability, and operational efficiency. Throughout the implementation and design process, H1 Systems was responsible for successfully managing the certification procedure of the data hall.

What does the TIER III Constructed Facility certification mean?

The TIER certification system, developed by Uptime Institute, is a globally recognised standard framework for data centres. The TIER III Constructed Facility certification verifies that a facility not only complies on paper, but also operates as a fully functional system meeting all TIER III requirements.

During the certification process, Uptime Institute performs a live operational assessment of the facility’s electrical, mechanical, and infrastructure elements, benchmarking them against the TIER Standard: Topology. This provides a reliable guarantee that the system is free of hidden vulnerabilities and is able to ensure long-term availability, resilience, and operational efficiency.

Nvidia és H1 Systems csoportkép

NVIDIA x H1 Systems – Driving Digital Transformation in Hungary

NVIDIA x H1 Systems – Driving Digital Transformation in Hungary 2048 1536 H1 Systems Mérnöki Szolgáltatások Kft.

Just like data center technologies, we are constantly evolving and adapting — because our clients’ competitive advantage can only be secured through future-ready infrastructures. In recent days, we’ve made a significant step forward in this journey, one that we believe will open new horizons for Hungary’s digital transformation.

We had the honor of hosting NVIDIA’s regional team in Budapest for three days — their first visit to Hungary — where we gained deep insights into the technological ecosystem that underpins the AI revolution and ensures reliable operations. Together, we also engaged with leading companies and institutions that play a key role in Hungary’s digital transition, allowing us to shape a comprehensive and realistic strategy to ensure Hungary’s active participation in the digital revolution that is reshaping the present and defining the future.

Nvidia H1 Hun-Ren
Joint visit of NVIDIA and H1 Systems at the HUN-REN headquarters in Budapest (left), Mihály Németh (CEO, H1 Systems) and Jensen Huang (CEO, NVIDIA) at the GTC Europe conference in Paris (right).

We are grateful to the NVIDIA team for the opportunity to learn, and we are grateful to our clients and institutional partners for engaging in this shared dialogue. This is only the beginning — our mission is to build extensive competencies and create value for enterprises, institutions, organizations, and for Hungary as a whole.

Uptime Institute Official Business Partner

H1 Systems Becomes an Official Partner of Uptime Institute – A Professional Milestone in Digital Infrastructure

H1 Systems Becomes an Official Partner of Uptime Institute – A Professional Milestone in Digital Infrastructure 800 450 H1 Systems Mérnöki Szolgáltatások Kft.

H1 Systems has officially earned partner status with Uptime Institute – an international recognition that represents not just a prestigious title but a significant professional qualification. This designation certifies our expertise and experience in delivering high-quality data center infrastructure solutions.

Globally regarded as the benchmark for digital infrastructure excellence, Uptime Institute sets the standard in the design, construction, and operation of data centers. Partnering with the Institute requires meeting exceptionally high professional criteria – which is why we are especially proud to have joined this exclusive, globally recognized professional community.

Professional Credibility and Strategic Thinking

Achieving partner status is not the result of a single project or successful audit, but a recognition of consistent, long-term professional development and commitment to quality. For years, our engineers at H1 Systems have participated in Uptime Institute’s training programs, earned multiple certifications, and demonstrated their expertise through numerous data center projects both in Hungary and internationally. We combine this practical knowledge with a forward-looking, strategic approach — delivering solutions that meet not only today’s challenges, but are also prepared for tomorrow’s demands.

End-to-End Data Center Services – From Concept to Operation

Our service portfolio covers the entire lifecycle of data centers: from concept development and design through construction to ongoing operation.

This integrated approach ensures that our clients’ infrastructure performs with the highest levels of operational reliability and efficiency — whether it’s a Tier certification project, a greenfield investment, or the optimization of existing systems.

Official Business Partner – A new chapter in a trusted partnership

Our collaboration with Uptime Institute is not new — over the past years, we’ve built mutual trust through several joint projects and professional engagements. Now, this relationship has evolved into an official partnership, opening new opportunities for closer collaboration and shared value creation.

The U.S.-based organization works with a limited number of partners globally, making it an even greater honor for H1 Systems to be among the selected few.

Why H1 Systems?

  • Engineering competence: Our experts hold multiple Uptime certifications
  • International experience: We deliver successful projects in Hungary, across the region, and in Western Europe
  • Future-focused vision: We design data centers that are both technologically and commercially sustainable and scalable

This partnership reaffirms that we are on the right path — continuing to deliver solutions that meet, and often exceed, the most rigorous international standards.

Uptime Institute

Uptime Institute is the Global Digital Infrastructure Authority. For over 30 years, the company has established industry-leading benchmarks for data center performance, resilience, sustainability, and efficiency, which provide customers assurance that their digital infrastructure can perform across a wide array of operating conditions at a level consistent with their business needs. Uptime’s Tier Standard is the IT industry’s most trusted and adopted global standard for the design, construction, and operation of data centers – the backbone of the digital economy.

With its Tier Standard and Certifications, Management & Operations reviews, SCIRA-FSI financial sector risk assessment, Sustainability Assessment and broad range of additional risk and performance assessments, Intelligence research services, and accredited training courses completed by over 90,000 data center professionals, Uptime has helped thousands of companies in over 100 countries to optimize critical IT assets while managing costs, resources, and efficiency.

Uptime Institute is headquartered in New York, NY, with offices in London, Sao Paulo, Dubai, Singapore, and Taipei.

Another milestone in H1 Systems’ data center competence

Another milestone in H1 Systems’ data center competence 595 807 H1 Systems Mérnöki Szolgáltatások Kft.

In recent years, data center investments have been growing rapidly across the globe. With the rise of digitalization and AI-driven applications, more and more organizations recognize the importance of high-reliability, high-availability infrastructure.

At H1 Systems, we have been working consistently for years to ensure that we are not only a contractor for our clients—but a strategic technology partner as well.

Huawei Value Added Partner: The Highest Level of Recognition

H1 Systems has achieved the Huawei “Value Added Partner” certification, which represents the highest level within the manufacturer’s partner structure in the data center infrastructure segment.

This status reflects not only technical excellence, but also strategic cooperation—enabling us to represent our clients’ interests at the highest level, even in large-scale, highly complex projects.

Technological Expertise = Real Competitive Advantage

In today’s data-intensive landscape, basic product-level knowledge is no longer enough. To deliver real value, we must apply integrated solutions, and up-to-date expertise—so our clients can make the best possible decisions when planning and implementing their infrastructure investments.

This Huawei partner status confirms that our specialists have a comprehensive understanding of Huawei’s data center infrastructure portfolio, and are fully equipped to design and implement tailored, scalable, and future-proof solutions.

Continuous Development, Long-Term Commitment

This recognition is not a final goal but a new milestone on a long journey: one where we aim to support our clients’ business goals with reliable, practical, and up-to-date knowledge in all relevant technologies.

Whether it’s building a new data center, modernizing existing infrastructure, or implementing AI-compatible systems, our mission remains unchanged: to deliver customized, efficient, and reliable solutions—without compromise.

Thank You to Our Team and Partners

This achievement would not have been possible without the dedication and professional preparation of our colleagues. We thank our team for their commitment, training efforts, and collaborative spirit.

We are also deeply grateful to our partners for their continued trust and cooperation. Together, we are building resilient and future-ready data center systems for the long term.

The Future of Security Technology: Artificial Intelligence, Trends, and Cybersecurity Challenges – An Expert Interview with Martin Grennel

The Future of Security Technology: Artificial Intelligence, Trends, and Cybersecurity Challenges – An Expert Interview with Martin Grennel 1200 630 H1 Systems Mérnöki Szolgáltatások Kft.

How can AI redefine facial recognition surveillance? How serious are the cybersecurity risks of IoT systems and data centres? Besides image quality improvement, what are the most important trends in security industry? Some of the most important questions of security industry today. We discussed these and other interesting topics with one of the leading minds of this industry, successful entrepreneur and leader, Martin Gren, co-founder of Axis Communications. Martin was the keynote speaker at H1 Systems Safe Space Meetup in Budapest.

In the Hungarian media, due to certain political overtones, the possibility of facial recognition surveillance of events is nowadays very much emphasized. From a strictly non-political point of view, how do you think AI can or should change video surveillance.

AI can make operators’ work much easier. Regarding facial recognition, there are different levels of acceptability. It’s ultimately up to politicians to determine these boundaries. For instance, if something is missing in the store and you search for  persons entering/exiting in video footage, this is what a normal security guard would do. Automating that process is, in my view, a perfectly legitimate application of AI and facial recognition technology.

However, maintaining a blacklist of people who are prohibited from certain locations and automatically screening against that database is a more sensitive application. In these cases, we need to develop a legal framework to define what is permissible. In some scenarios, you may have consent to use facial recognition, such as in high-security areas with facial recognition access control systems. I believe this is also a legitimate application.

As you can see, this isn’t a simple black and white issue. It’s not about declaring facial recognition as either always legal or always banned. The truth lies somewhere in between and you need to consider several factors.

Cybersecurity is usually thought of in the context of ‘don’t get a virus’ or ‘don’t fall victim to bank fraud’ (there are also many stories in the media of this happening). However, there is less discussion of the security risks of some elements of the ubiquitous IoT world and how to defend against threats. What is your opinion about that, about this special security risk or security challenge?

I believe this is a risk that must be taken seriously. There have been numerous attacks where the security system itself was the weak link. About ten years ago, there was a hack involving a cheap camera from China with a hard-coded root password. This security vulnerability was easily exploited and led to a major denial of service attack that brought down the country of Liberia’s internet and many high-profile websites.

The worst vulnerabilities have been addressed, but some companies are known for being slow to address cybersecurity issues. It’s a question of transparency. Our company maintains an open approach. We provide a software bill of materials that details all the open-source components we use. When an issue arises with any component, we acknowledge it and work to upgrade it immediately. I think our company has established a solid ten-year track record of taking cybersecurity incidents seriously.

We maintain a bug bounty program where people who find and disclose vulnerabilities to us receive compensation based on the severity of the issue. We’ve made payouts to bug hunters approximately five to ten times so far.

What new cybersecurity challenges does cloud computing and data centres pose?

When connected to the cloud, a zero-trust network becomes truly critical. Many security systems are air-gapped and not connected to the internet, though they typically still have VPN login capabilities. For genuine cloud-connected cameras, cybersecurity must be elevated to an even higher level. It’s crucial to ensure systems are consistently updated and maintained.

What kind of trends do you see in the security industry these days. A few hints were mentioned in your presentation, but would you please summarize them to our readers too.

Sure. Image quality is obviously improving every year. I can genuinely say that our company has a lead when it comes to image quality.

We’re seeing the new compression standard, AV1. It’s a multimedia standard already widely supported by YouTube, Netflix, Chrome, and virtually all cell phones. It provides additional 20% efficiency – using 80% of the data needed for the same quality stream in H.264, this means lots of data storage savings. On top it’s license-free and protected by a consortium that blocks patent trolls, I really believe in this open standard. Our partners are with us on this – both Milestone and Genetec have implemented support for AV1. I’m confident the entire industry will support this within a few years.

We’re also seeing other trends, like simplified installation, which has been developing for some time. This includes capabilities like remote configuration and force positioning. You can rotate individual optical sensors, pan, tilt, and rotate again – it’s a very useful feature. This makes installations more reliable. If you need to reconfigure a warehouse, for example, it’s no problem. You only need to access the web interface of the product.

What is your opinion about the impact of 5G technology in the security industry?

5G is a connectivity technology. It doesn’t directly affect cameras because most of our devices are stationary mounted. We do have body-worn cameras that may support 5G. However, most markets that Axis serves involve permanently connected cameras.

We have installations like highway cameras that benefit from 5G, but generally network availability already exists when our products are used.

Another hot topic in the media nowadays is the smart cities story. How can urban camera systems help to develop, improve and implement smart city concepts?

We implement many solutions in smart cities. We’ve always done traffic monitoring, license plate recognition, and counting. We can monitor traffic flow, detect excessive vehicle noise through noise sensing, and use radar for speed checking. We can integrate these capabilities into systems to track average speeds or identify vehicles that are too fast or too noisy. I personally look forward to implementing the noise sensors, as they can help address issues like noisy motorcycles at night.

This is how camera systems can help create more liveable and better urban spaces. It’s a very quiet but powerful application. At Axis, we began investing in IP audio about 10 years ago. That segment is now starting to take off, so we’ve added many more products to that portfolio. We began with the IP horn speaker as a deterrent, and now we have a strobe speaker that allows two-way communication. It features a strobe with flashing LEDs that we’re demonstrating here as a disco light. This can grab attention and serve as a deterrent in various applications.

About Martin Gren

Studied advanced computer science and electronics and in 2015 he was appointed Honorary Doctor at Faculty of Engineering, LTH, Lund University, for his qualities as an entrepreneur and leader.

As the co-founder of Axis, Dr. Gren often attends many global security events and receives great feedback for his speaking skills. Martin Gren is also a proud owner of several awards, including the H.M. the King’s Medal, from the Swedish Royal Court in 2015, for “significant contributions to Swedish industry” and he was named the most influential person in the global security and fire industries by the international fire and security exhibition (IFSEC) in 2013 and 2017. Dr. Gren was also presented as Sweden´s most successful entrepreneur in the final of Ernst & Young Entrepreneur of the year 2009.

About Axis Communications

Axis enables a smarter and safer world by creating solutions for improving security andbusiness performance. As a network technology company and industry leader, Axis offers solutions in video surveillance, access control, intercom, and audio systems. They are enhanced by intelligent analytics applications and supported by high-quality training.Axis has around 5,000 dedicated employees in over 50 countries and collaborates with technology and system integration partners worldwide to deliver customer solutions. Axis was founded in 1984, and the headquarters are in Lund, Sweden.More information about Axis: www.axis.com.

H1 Safe Space – A Glimpse Into the Future of Security Technology

H1 Safe Space – A Glimpse Into the Future of Security Technology 2048 1365 H1 Systems Mérnöki Szolgáltatások Kft.

Where is the security industry headed? How are global manufacturers innovating? What role does AI play in transforming video analytics—and how can it be turned into a business advantage? These were just some of the questions we explored during the very first edition of H1 Safe Space, H1 Systems’ new event series dedicated to building technology and security innovation.

Held at the end of April, the event brought together international experts, forward-thinking topics, and inspiring conversations. With this new meetup series, our goal is clear: knowledge sharing, professional dialogue, and maintaining a shared competitive edge.

A Forbes Interview to Kick Off the Event

Our keynote speaker, Martin Gren, co-founder of Axis Communications, is not only a true pioneer in the security industry, but also someone whose unique perspective on innovation caught the attention of Forbes Hungary.

We were honored to host him at the H1 Safe Space—and thrilled that Forbes conducted an in-depth interview with him during his visit. The resulting article captures Martin’s vision perfectly: how we can embrace technological change with confidence and transform it into a strategic advantage.

Read the full article here: Forbes interview with Martin Gren

Presentations From the Frontlines of Innovation

Our guest speakers offered deep insights into the current and future trends shaping the industry. From autonomous drone nests and AI-driven video analytics to access control and next-generation smart buildings, attendees gained valuable perspectives across a range of cutting-edge topics.

More Than an Event – A Professional Experience

At H1 Systems, we believe that every meetup or conference is more than just a gathering—it’s a defining experience. Based on the feedback we received, it’s clear that we succeeded in bringing fresh perspectives and new energy into the often hard-to-grasp world of engineering and technology.

We would like to thank all our guests, clients, and speakers for their contributions. We hope everyone left our headquarters with valuable insights and inspiration for the future.

140 MW Data Center Under Construction in Vietnam with H1 Systems’ Expertise

140 MW Data Center Under Construction in Vietnam with H1 Systems’ Expertise 1958 1406 H1 Systems Mérnöki Szolgáltatások Kft.

Southeast Asia’s rapid economic growth and digital transformation have reached a significant new milestone: on April 23rd, construction officially began on the Tan Phu Trung Data Center in Ho Chi Minh City, a major investment by Viettel. The facility, located on nearly 4 hectares of land, is designed with a total capacity of 140 MW and sets a new standard in digital infrastructure in the region.

The H1 Systems team is proud to contribute to this ambitious project by providing design management services throughout its multi-phase development. The goal is nothing less than to create a world-class data center that meets not only today’s needs but also tomorrow’s—especially in terms of the high-performance computing demands of artificial intelligence.

Technical Excellence in a Tropical Climate

The Tan Phu Trung Data Center is being designed and operated according to international Uptime Institute Tier III standards. With an average power density of 10 kW per rack—2.5 times the national average in Vietnam—and a maximum rack capacity of up to 60 kW, the facility is well-equipped to serve the resource-intensive requirements of AI models and other high-compute applications.

What makes this project particularly noteworthy is its expected Power Usage Effectiveness (PUE) of less than 1.4—an exceptional achievement in a climate with extreme heat and humidity. This level of efficiency is made possible through the use of cutting-edge technologies, innovative materials, and optimized operational strategies.

A Phased Project with a Long-Term Vision

Phase one of the project is expected to go live in the first quarter of 2026, while full completion is scheduled before 2030. Thanks to its scalable design, the data center will be able to grow in step with the region’s digital economy and evolving client needs.

H1 Systems – Expertise with Global Reach

For H1 Systems, this project is yet another example of how our engineering expertise can deliver at a global level. With our design management services, we help ensure the facility meets the highest international standards while adapting to local conditions. Our engineering know-how and integrated approach provide the foundation for a truly future-ready data center—starting at the drawing board.

Beyond PUE – What Makes a Data Center Truly Sustainable? An Interview with Dr. Jon Summers

Beyond PUE – What Makes a Data Center Truly Sustainable? An Interview with Dr. Jon Summers 714 445 H1 Systems Mérnöki Szolgáltatások Kft.

Why is liquid cooling so efficient in data centres and what is the best coolant? What are the best sustainability metrics for data centres today? Is a data centre less energy efficient than an incandescent light bulb? Jon Summers, Scientific Lead in Data Centres at Research Institutes of Sweden (RISE), Adjunct Professor of Fluid Mechanics at Lulea Technical University in Sweden and Visiting Professor of Thermofluids at the University of Leeds, answered our questions at the H1 Systems DC Meetup in Budapest.

In some of the previous blog articles, we have covered the Research Institutes of Sweden (RISE), but for the possible new readers, can you just say a few sentences about it? What is the main area of activity there and what are the main achievements?

RISE is a very large research organisation, and it covers a lot of disciplines in science and engineering. The unit that I work for, is focused on data centres, our job is to look at operational efficiency and to look into rigorous testing and validation of some of the new equipment that’s being used in data centres now, particularly on the cooling side of things. We’re going back to liquid cooling now. It’s like going back to the future, isn’t it?

RISE is focused on sustainability and operational efficiency and future technologies. And it’s all about IT. I mean, we don’t really work with what’s happening in IT. It’s a field that we don’t have a lot of control over. But what you put around it, the system you put around IT, is where our research focus is. And we’re part of the Digital Systems Division, which has a computer science department. And the ICE Data Centre unit is part of that computer science department.

Jon Summers at the 3rd H1 DC Meetup in Budapest, February 26th, 2025


Talking about liquid cooling and the ‘back to the future’ effect, can you summarise the concept and give us some ideas on the best cooling fluids?

One of the speakers at the meetup mentioned in his presentation that Lenovo was using de-ionized water for their direct-to-chip system. And NVIDIA is pushing PG25, which is propylene glycol, 25 per cent glycol with water, with additives. This is for direct-to-chip systems, but you have to remember that we have to make the system completely watertight. Because if any of that leaks onto the IT equipment, the very, very, very expensive IT equipment, it can damage it. One aspect of it is that we’re using coolants which, if they leak, can damage the IT equipment.

The two-phase direct-to-chip system, which was also mentioned, is another way of doing direct-to-chip liquid cooling. There are two reasons why you use a liquid that changes phase. On the one hand, it usually improves the heat transfer because – this is on the diagrams that I had in my presentation – the thermal resistance goes down, so it’s got a much wider range of extracting the heat. The other thing is that it’s usually a dielectric, so if it leaks it’s not going to damage the IT equipment.

That’s the dilemma from the direct-to-chip side. If you go single-phase, you’re probably going to be using a water-based system, and you really have to be careful about leaks. Some manufacturers have looked at this and said, well, can we run it under pressure so that if there is a break in the hose or a crack, instead of liquid coming out, it sucks in air. It’s not the liquid that comes out or the water that comes out, it’s the air that’s sucked in and then you can fix the problem.

But that’s one class of liquid cooling. There’s another class of liquid cooling, which is called immersion liquid cooling, where you put all the electronics, even the power supplies, into a dielectric liquid. That’s not guaranteed by NVIDIA, so the reason it’s not happening a lot with AI now is because, as I understand it, NVIDIA won’t say they’re going to guarantee their equipment for immersion. And there are other complexities and physical complexities like what we call signal integrity, to put it differently what happens because the signals between the GPUs go over a very fast interconnect. And sometimes we don’t know how well that works when it’s submerged. That’s a piece of research that’s going on right now.


We have heard a lot, even here today, about PUE as a key metric for data centre efficiency. Can you summarise your view on data centre sustainability metrics?
PUE, power usage effectiveness, along with a couple of other metrics like water usage effectiveness and so on, are classified as sustainability metrics, but they don’t really tell you the whole story. PUE is an interesting metric. It was first introduced in a paper at a conference in 2006 by Belady and Malone, who were working for HP at the time. That was before the Green Grid picked it up. They wrote a paper saying it was a ratio of two powers. They monitored it at a point in time and calculated it as the power consumption of the whole data centre divided by the power consumption of the IT.

Then they realised later, when it went to the Green Grid, that this value is very much affected by the season, by the temperature outside. Because your cooling infrastructure requirements change as the seasons change, the energy consumption of the cooling infrastructure is very much linked to the outside temperature. This is why they decided that this should be measured over a whole year, and it became what’s called an annualised metric.

The thing that PUE has done is that it has helped data centres improve their performance. I don’t think it’s a very good metric for comparing data centres. However in the 2006 paper, it said that government agencies like the EPA – the Environmental Protection Agency – could use this metric to justify building the data centres. And it was a metric that was used to mandate building data centers in geographic locations like Amsterdam, Singapore and other locations.

But a target PUE makes it a bit divisive because you have very different climates, very different environmental conditions. And it’s also very complex because even in my presentation I showed how IT can use more power if you run hotter. And of course ASHRAE (the American Society of Heating, Refrigerating and Air-Conditioning Engineers) has said run your IT hotter. You’re using more power on the IT side, but then you’re using less power on the cooling side, so your PUE is going in the right direction: it’s going down. But are you using less energy or more energy? I think sustainability metrics should focus first on what is the data centre doing or what’s the productivity of the data centre. And then how much is that costing us in terms of kilowatt-hours of electrical energy.

Jon Summers at the 3rd H1 DC Meetup in Budapest, February 26th, 2025

And the other thing is the cooling system supported by the use of water. It’s fine if it’s in a geographical location where there’s no water stress, but if it’s in a location where there is water stress, then the environmental impact is so much higher. Water efficiency metric, if you want to use it as a sustainability metric, depends on where the water is being used. Because it doesn’t really matter if you’re using half a litre per kilowatt hour in a place where there’s no stress on the water system. But at the end of the day, if you’re using potable water, there’s energy associated with that too. That is not factored into the PUE because it measures the energy, or the ratio of electrical energies.


When you talked about energy consumption and energy efficiency in your presentation, you made a very interesting comparison between chips and light bulbs. Could you summarise that for our readers?
You’re putting energy into the system, and that energy is designed to produce digital information. There’s a scientific approach to measuring the energy value of the information. And if you measure that energy value today, it’s about 0.03% of the energy consumed from the grid that goes into the information. That’s the part you want.

You must pay for every kilowatt hour that the data centre uses. And what you want is a digital service that uses only 0.03% of the energy associated with the data centre. About 99.97% of the energy goes into heat, and that is a problem. The incandescent light bulb was banned because it was so inefficient. Only 5% of the energy went into the light, which is what you want, but you’ve got to pay for the electricity, the power for the light. And what you want is the light, but if you’re only getting 5% of it, it’s not very efficient. It really demonstrates the fact that data centres, if you look at them in their pure form, what you want divided by what you have to pay for, demonstrates that they’re very inefficient, energy inefficient.

AI – Is it a blessing or a sustainability challange?

AI – Is it a blessing or a sustainability challange? 768 465 H1 Systems Mérnöki Szolgáltatások Kft.

What are the latest infrastucture develoments in data center industry? Liquid cooling or hybrid thermal management systems, including both air and liquid cooling? How does Vertiv cooperate with NVIDIA? Tomislav Šarić, Sales Director Indirect Business, CEE at Vertiv answered our questions at H1 Systems DC Meetup III. in Budapest.

I’ve read the news piece about your company’s NVIDIA partnership. It says: ’Vertiv brings its high-density power and cooling infrastructure expertise to the NVIDIA Partner Network to better support adoption of accelerated computing and AI workloads’. What does this cooperation/partnership mean for Vertiv? What opportunities does it give to you?

In 2024 Vertiv joined the NVIDIA Partner Network (NPN), providing wider access to Vertiv’s experience and full portfolio of power and cooling solutions.

NPN is a global program for technology partners who offer solutions built on, or powered by, NVIDIA technologies. Among leading software vendors, cloud service providers, solution providers, and system integrators, Vertiv joined the network to offer its expertise in addressing the unique infrastructure challenges presented by accelerated computing. NPN provides access to a range of benefits, including technical support, training and collaboration opportunities, helping partners deliver innovative solutions to their customers.

According to Barron’s, NVIDIA CEO Jensen Huang directly citied the company’s partnership with Vertiv as a way to create effective cooling solutions for customers dealing with the increased power demands of new AI GPUs entering the market 

Vertiv has collaborated with NVIDIA in research, development and engineering for multiple years, designing innovative products and solutions that support the deployment of NVIDIA technologies globally. We have combined our leadership in power and cooling solutions with NVIDIA’s cutting-edge platforms to help meet the demands of the most compute-intensive applications and support the deployment of AI infrastructure across the globe. Now, we are collaborating to build state-of-the-art liquid cooling solutions for next-gen NVIDIA accelerated data centres powered by GB200 NVL72 systems

For Vertiv, this collaboration opens up new opportunities to develop and deliver next-generation solutions tailored for AI infrastructure. It enables us to work closely with NVIDIA and its ecosystem, gaining deeper insights into evolving industry needs while enhancing our offerings to better support customers deploying AI workloads. Additionally, it strengthens our market reach, positioning Vertiv at the forefront of AI-driven data center innovation and reinforcing our role as a trusted critical infrastructure partner.

AI changes everything these days, including data center infrastucture requirements. Existing power and cooling infrastructure will require significant upscaling to support the unprecedented demand of accelerated computing. What are the most important considerations for AI infrastructure deployments?

Dealing with AI workloads requires an evolution in the architecture of data centers, especially in terms of power and cooling requirements.

To accommodate this shift, data centers will need to expand power capacity across the entire infrastructure, from the grid to chip. In addition to power, traditional air-cooling systems are often no longer sufficient for AI hardware. AI chips require typically five times more cooling capacity than traditional servers, pushing the industry toward adding liquid-cooling technologies as their key heat rejection strategy. This shift is essential to provide effective heat management in these high-density environments.

Enterprises developing an AI strategy needs to consider the ability of their infrastructure to support the new workloads. Besides having more GPUs and faster networking solutions, they also need to ensure that their data center power and cooling systems can keep up with the requirements. This should be factored into their ESG e􀀧orts and strategy as well.

Some workloads, including AI models with smaller number of parameters can be deployed at the edge to meet latency and security requirements. Service providers and enterprises can evaluate modular, prefabricated data centers in the market for edge data centers. These data centers are faster to deploy and may come with more advanced power and cooling technologies.

Vertiv is already supporting customers with liquid cooled systems and is working directly with industry ecosystem partners to develop standards, along with various architectures to support different liquid cooling scenarios. Vertiv offers coolant distribution units (CDUs) that utilize existing heat exchange infrastructure via more traditional air exchange to pull heat from liquid cooling systems.

Vertiv offers the High Performance Computing (HPC)/High Density (HD) power and thermal architecture for any AI solution using its innovative liquid cooling solutions.

What can be said about the current development of data centres?

Dealing with AI workloads requires an evolution in the architecture of data centers, especially in terms of power and cooling requirements. A recent Vertiv study showed that traditional IT racks, which once operated with 5-10 kW , are rapidly evolving to handle workloads exceeding 40 kW per rack—and even surpassing 100 kW. Computing infrastructure accelerated with GPUs, such as NVIDIA’s H100 chips, are significantly more power-hungry and heat-intensive than conventional servers.

To accommodate this shift, data centers will need to expand power capacity across the entire infrastructure, from the grid to chip. In addition to power, traditional air-cooling systems are often no longer sufficient for AI hardware. AI chips require typically five times more cooling capacity than traditional servers, pushing the industry toward adding liquid-cooling technologies as their key heat rejection strategy. This shift is essential to provide effective heat management in these high-density environments.

Vertiv’s high-density power and cooling solutions are designed to support the next generation of GPUs running the most compute-intensive AI workloads safely, at optimal performance and with high availability.

Vertiv’s portfolio of liquid cooling technologies, such as Vertiv™ Liebert® XDU coolant distribution units, Vertiv™ Liebert® XDM split indoor chillers, and Vertiv™ Liebert® DCD rear-door heat exchangers, cover a wide range of application requirements. The Vertiv™ Geist™ rack power distribution units (PDUs) family has been extended to accommodate higher power draw within the rack, minimising footprint while maintaining high efficiency.

How do you see the latest infrastucture develoment in data center industry? What are the advantages here and what could be mentioned as disadvantage?

While there is excitement across industries about the different use cases AI/GenAI can support, their increased power demands are creating challenges around sustainability and performance that industry needs to address.

The massive amounts of power used by data centers is already leading toward regulations limiting new data center builds, highlighting the need for the industry to be more energy efficient and reduce dependency on power from the grid.

Vertiv’s vision for the future of data center power revolves around dynamic power management systems, drawing from a hybrid of energy sources, supported by increased deployment of uninterruptible power supplies (UPS) and battery energy storage systems (BESS).

In many cases high performance compute workloads now require liquid cooling systems to remove heat, due to changes in chip architecture. Vertiv and other industry ecosystem players are currently evolving standards for the future of liquid cooled infrastructure, while still seeking to provide liquid cooling systems into existing brownfield data centers.

Challenges still exist and while the ecosystem is being driven by AI hyperscale requirements, smaller enterprise colocation facilities will still need to be supported.

One of the most important datacenter cooling technologies these days is liquid cooling. What is your opinion about this technology and how can you see its spreading in this region of the globe?

Currently, data centers support rack power requirements in excess of 20 kilowatts (kW), but the market is headed to 50 kW or more. Newer-generation central processing units (CPUs) and graphics processing units (GPUs) have higher thermal density properties than previous-generation architectures. In addition, server manufacturers are packing more CPUs and GPUs into each rack to meet the accelerating demand for high-performance computing and AI applications.Air processing is now showing its limits. Traditional air cooling can’t cool these high-density racks efficiently and sustainably.

As a result, data center operators are investigating their liquid cooling options. Liquid cooling leverages the higher thermal transfer properties of water or other fluids to support efficient and cost-effective cooling of high-density racks and can be up to 3000 times more effective than using air. Long proven for mainframe and gaming applications, liquid cooling is expanding to protect rack-mounted servers in data centers worldwide.

Liquid cooling is a more efficient way of cooling the data center for two reasons:

  1. The supply temperature of the working fluid can be elevated to maintain processor operating conditions, without increasing fan power as the cooling is directed at the hottest components, typically the processor. We acknowledge that the heat transfer between the processor and the cold plate is much more efficient than the heat transfer between the processor and the surrounding air in case of a traditional air cooling system, thus benefitting the overall efficiency of the datacenter.
  2. The return water temperature from the racks, being elevated compared to traditional air cooling, could enable the heat recovery in a much efficient way than in an air cooled data center.

With the constant increase of applications requiring increased computing power, there will be a move to innovative thermal management technologies to better manage these higher power densities. We expect many data centers will introduce hybrid thermal management systems, including both air and liquid cooling.

Can we talk a bit about ’prefab’ data center products? Where are these the most popular and what can be the reason for their success?  

Over the last decade or so, there has been a change in data center builds from conventional “brick and mortar” builds where data center operators select and size system components and engineer them to work together, then construct the building, and, when data center building is completed, install and commission the equipment. Today, modular data centers are designed, manufactured, and tested off-site while the preparation of the site takes place in parallel, leading to 40% or more time savings versus a traditional new-build data center. Prefabricated modules are meant to be as plug-and-play as possible, reducing onsite labor requirements and onsite process logistics complexity.

The advantages of this are rapid, efficient design, lower risk, and cost certainty due to factory integration. Modular data centers are scalable for future extensions, have repeatable designs, and are high quality due to the control possible through factory integration. The simplistic assembly allows modules to be shipped quickly by road, rail, or sea.

  • Vertiv™ SmartMod™: Prefabricated Modular Data Centers up to 100kW normally fall under all-in-one modular data centers, where all the equipment necessary for normal data center functionality is placed within a single transportable module. Vertiv can support this range with its Vertiv™ SmartMod™ that is a perfect fit for IT deployments between 2 and 14 racks or 100 kW or less.
  • Vertiv™ SmartMod™ Combo: Standardized prefabricated data center offerings for IT deployments from 200 kW to 600 kW and up to 104 IT racks in total can be addressed with the Vertiv™ SmartMod™ Combo. The modules are shipped in prefabricated sections, then connected and sealed at your site by experienced Vertiv personnel to create a fully functional data center with dedicated White Space and external Vertiv™ Power Module. SmartMod Combo leverages core Vertiv™ Critical Power, Thermal Management, and Monitoring & Control Technologies.
  • Vertiv™ MegaMod™ :  Provides a High-Quality Prefabricated Modular Data Center Solution that can be deployed in expandable units of 0.5 or 1 MW for IT Loads up to 2 MW or more. MegaMod™ provides everything you need to get started with a fully equipped modular data center, from external power rooms, to cooling, racks, monitoring and fire protection. In addition, Vertiv also can provide end-to-end services for a worry-free startup and ongoing operations, including deployment, commissioning, ongoing maintenance, spare parts, and ongoing trainin
  • Vertiv™ TimberMod™: Vertiv™ TimberMod™ is the variant of the Vertiv™ SmartMod™ and Vertiv™ Power Module using mass timber as structural element instead of steel. This alternative supports customer’s sustainability objectives by using a more environmentally friendly material that can minimize resource depletion and can lower emissions. ​

Vertiv™ SmartMod™ HDX: Vertiv™ SmartMod™ HDXLatest developments in AI, IoT, cryptocurrencies, AR/VR reality and the exponential growth in data, means that today businesses need access to computers capable of performing complex workloads. This in turn has resulted in a need for data centers where a single IT rack can support densities of 20 kW and higher. The Vertiv™ SmartMod™ HDX is addressing this need with a simple, scalable data center design that uses pre-engineered Vertiv™ building blocks to create a full solution – the Power Module, IT Hall and Chiller Skid. This next generation High Power Density data center utilizes the Vertiv™ Liebert® DCL or active Vertiv™ Liebert® DCD cooling solutions to support rack density up to 50 kW/rack.

“We will also learn a lot from this project”

“We will also learn a lot from this project” 768 465 H1 Systems Mérnöki Szolgáltatások Kft.

Çağatay Yılmaz and Henrik Barestrand from the Swedish RISE Institute on the EU Energy Efficiency Directive

How can RISE bridge the gap between academia and industry? What are the current trends in sustainable digitalization? How should sustainability indicators be used in data centers? We talked to Çağatay Yılmaz, Project Manager of ICE Data Centre (RISE) and Henrik Barestrand at the HEATWISE Meetup in Budapest.

Can you say a few words about the role of the RISE Institute in the HEATWISE project? What are you doing in Sweden and how do you cooperate with the other project partners?

CY: From Sweden: RISE is owned by the Swedish government. We are trying to bridge the gap between academia and industry. Basically, we try to increase the level of technology readiness with open innovation practices. We work with organizations and help them to make sure that their products are ready for market and comply with standards.

The RISE Research Institute is quite a large organization: we have 3,300 people. Our unit where I work, ICE Data Center, is located up north in the city of Luleå. ICE Data Center focuses on sustainable digitalization with a focus on data centers. This is our role in the HEATWISE project too. I could say that we represent the data center business. But this project isn’t just about data centers, it’s about decarbonizing buildings in general. So, there are other partners in the collaboration that represent building sites, that deal with management communication.

HB:  What we’re doing is helping companies develop products. Start-ups for example, big companies, research departments. We collaborate with a lot of companies. The principle is that we support their research departments. Let’s say there’s a startup company with a product, and we’re evaluating that product in the context of data centers as well. We help them develop the technology, like what we have done in the HETAWISE project.

Let us move away from the HEATWISE project for a moment! You mentioned in your presentation that one of your focus areas is sustainable digitalization. Can you name some of the main trends or focus areas in sustainable digitalization? What can be said about this area today?

CY: The EU wants to decarbonize industry. I don’t think they prioritized data centers before, but now they understand that they are responsible for a lot of energy consumption. And it is not just data centers, but all sorts of digital technologies that are spreading around the world. Think of your fridge and probably even your vacuum cleaner: they are all smart now. These technologies need to be more sustainable. We focus more on the cloud side, where the data from the Internet of Things (IoT) is collected. But the EU has just pointed out that this is a risk.

One of the main trends is to reduce the carbon footprint of these digital technologies. This is why the EU, for example, supports the refurbishment of digital technologies. The key words here are repair and reuse. Another example is when they forced Apple to use USB-C instead of their own plugs; the aim was that we should be able to use all the adapters in all our devices and we can only buy one adapter. Such initiatives or actions have been taken on the IoT side of the digital continuum.

But we are now talking about a slightly different story, about energy-intensive industries. I can give you an example. A rack as big as this table can now reach up to 200, 300 kilowatts. That is huge when you consider that a boiler that is not running all day is about 2 kilowatts. Now the EU wants us to focus on this, to make these systems more efficient, but most importantly to reuse the waste heat from these energy-intensive IT gadgets. That way the whole energy consumption is reduced. If we reuse the waste heat, edge data centers can replace the boilers in the buildings. So it would be a win-win situation. This is the only way to achieve climate neutrality in the long term.

And now there are a variety of markets that need this waste heat and with this HEATWISE project we are trying to look at different use cases. Rasmus can give you more information about how you can use this, use this waste heat in greenhouses, in factories, in commercial buildings, everything. They all need different heat loads. 


HB: What we’re doing is evaluating new technologies and putting them in the context of the data center. And what we’re trying to achieve is this energy harmony between all the players. Imagne the compute cloud where we have big players like banks, medical services, everything. Perhaps in the future we can enable them to put some of the work load on local servers in small communities and have it be beneficial for everyone, instead of exclusively having big data centers outside the cities. In that way, we are looking at ways to integrate it into city systems for heating.


CY: I can give another example. I think this might be useful. Imagine you have a fleet of cars. 10 cars and you have a parcel delivery company with those 10 cars. It is similar with data centers and our infrastructure. Depending on how much load you put on them, they have a consumption profile, in this case fuel and power consumption profile. Even if your car is not going anywhere, but the engine is running, it still consumes energy. In the data center world, 30% of peak energy consumption can be in standby mode.

Smart workload orchestration and intelligent use of your infrastructure can deliver huge energy efficiency benefits. Up to a certain point, the way we use this infrastructure hardware is like the way you use your personal computer. But with computing clouds, we started to virtualize it. That was a big step in the industry. It brought a lot of efficiency because multiple users could connect to one piece of hardware, they started using it. That is multi-tenancy and that is so important. But now we are always trying to go one step further. We are trying to do a better job of orchestrating and managing the IT infrastructure and extending the efficiencies that we bring to the market. This is one of the things we are trying to do in the HEATWISE project and more generally in our own ICE Data Center.

You mentioned EU Energy Efficiency Directive in your presentation. Can you summarize it in a few sentences?
CY: I believe that data center owners or operators are only interested in one thing: uptime. I’m not criticizing their motives. They don’t want their critical infrastructure to fail because we depend on these systems. Think of an air traffic control company or local authorities. If we were not within reach of these digital systems, we would be in trouble. We could survive without these digital systems before, but not now. We are dependent on them because we have automated a lot of our operations. The owners and operators of data centers have built an ecosystem that is only focused on not having downtime when we can’t reach the applications or services.

If we do not force the market to innovate while also caring about uptime, I guarantee you that no one will do anything about sustainability and efficiency. If I was the IT manager of the ICE Data Centre, I wouldn’t care how much energy I use. My job is uptime, to keep the data center running.

EU has taken an initiative, the first step towards a more sustainable future. Many of us have discussed whether it’s a good initiative or not. This is a competitive market, and we are competing with global players like the US and China, Japan and South Korea. If you think about our competitiveness with these markets, a new challenge of efficiency measures in the market raised a lot of question marks, no doubt. But I think we had to take this action. Now it’s going to be more difficult for us because we’re getting out of our comfort zone. We have to change; we have to be more competitive. But in the long term, I believe that European companies that have adapted to the European Energy Efficiency Directive and tried to introduce more efficient products can have a competitive advantage over other competitors from other markets. This is a good thing. You see, I’m trying to see the whole picture. I’m trying to motivate myself and the market that this initiative should have been taken.

In your presentation, you also discussed sustainability indicators for data centers. What do you think about them? Is there one universal indicator that could show everything, or do you believe in a combination of KPIs?

CY: Is there an all-encompassing formula that covers all aspects of efficiency? Like the theory of everything, a single line that explains everything. I think there is no such line, because there are different aspects in data centers. You can improve one KPI but ruin the rest. You can improve one KPI, but in doing so you may reduce the lifetime of the products, so you end up with higher carbon emissions with the embedded carbon of the new products you get. Unfortunately, the solution is not that simple. When I first started working with data centers, PUE was the first KPI I was introduced to. And in one of the meetings I had, I didn’t know it at the time, I met the person who wrote the European standards which adopted PUE. And I started complaining about it. I said this is nonsense, we cannot just adapt one KPI or base the whole strategy on one KPI. I think this document should be improved. He said: “Can you elaborate on that? Because I wrote this document. You can imagine that I started to sweat. But it turned out really good. We discussed it and decided that if we want to see overall efficiency, we have to look at several key performance indicators at the same time.

When you go to the doctor, he or she will not just give you a pill. First, he or she tries to understand what you need. What are the symptoms, what is the problem. It’s the same with data centers and infrastructure: it depends on the size, what grid you’re going to connect it to, if you can use the waste heat and so on. The answer depends on the conditions and infrastructure.

In terms of individual KPIs, to be honest, I am not a big fan of PUE, for example, because it is not a comparative metric. You can’t compare two data centers based on their PUEs. That KPI can show you that this data center is better in terms of energy efficiency, but the same data center could be failing in all other aspects. It can be easily manipulated. For example, go into the cooling system of your data center and increase the cold aisle temperatures of the data center. What would it do? Your IT infrastructure would suffer because it wouldn’t get enough cooling, but your PUE would be perfect (closer to 1). You would be sending more energy to IT because the computers would be using the internal fans and trying to fight it off.

I believe that every infrastructure is an individual and the teams that run the data center should know what they are doing and have a master plan to improve overall efficiency. HB: There is a story about how data centers have evolved from the beginning. I think in the past, cooling was the main issue with them, because cooling itself consumed a lot of energy. So, the PUE number used to have a specific purpose: to show the efficiency of the cooling. But that purpose is now better applied combined with other KPIs. If you were building a new data centre and you wanted it to be sustainable and future-proof at EU level, you would also need other KPIs for this reason. So, like in this project, we’re looking at a lot of KPIs. And maybe we will discover relationships between the different KPIs, and perhaps find something that can be simpler or something that needs to be considered more in context of performance. I think we will also learn a lot from this project.